One of our most popular units for its classic design, 180° adjustable heads, durability, and cost-effectiveness. The unit comes with two “EXIT” faceplates and one blank faceplate, for single or double-sided use. The faceplates include knockout chevrons, which allow the customer to customize the directional arrows. This exit sign operates at 120/277 VAC. Includes hardware for wall or ceiling installation. Comes with a modern and reliable NiCad battery providing 90 minutes of emergency lighting. The Remote Head Capable model allows for additional 3.6V remote lamp heads to be connected and wired at a different location where additional lighting is needed – See “Remote Head Capable” section for more information. The optional Self-Testing model is a great solution where manual testing is not possible or practical. The unit will perform the required NFPA testing and indicate the outcome of the test – See the “Self-Testing” section for more information. This unit also comes with an option for a 3’ Cord when hardwired installation is not an option.


Compatible Battery:  Battery Backup Model: BAA-36
Remote Head Capable Model: BAA-3618

Compatible Remote Head(s): RHP-L-3V, RHB-L-MV, RHB-WPL-MV
To use with with remote heads, please change the Operation Type above to Battery Backup + Remote Head Capable to ensure compatibility. Code at time of checkout must read: COMBO2-R-W-RH.

This product has been tested to meet all required U.S. standards by Underwriters Laboratories, Inc. (UL), the most widely recognized U.S. nationally recognized testing laboratory (NRTL).

UL Listed
This item has been tested and meets safety standards imposed by the Underwriters Laboratories (UL).

LED Lighting

LED Lighting
This product uses energy efficient and long lasting LED's.

Battery Included

Battery Included
This product contains a battery for backup power. The battery must be connected during installation.

Features

  • UL 924, NEC, OSHA and NFPA 101 Life Safety Code
  • Listed for damp location
  • All LED light! No SLA batteries, uses long lasting NiCads that are very low maintenance (battery included)
  • Two fully adjustable Emergency Light heads designed to point down and light the path of egress
  • Injection molded, 5VA flame retardant thermoplastic housing
  • 120/277 VAC operation
  • Universal mounting plate
  • Knock-out left/right arrows
  • Short circuit, voltage surge, brown out and low battery voltage disconnect protected
  • LED indicator light with push-to-test switch

Specifications

Dimensions (May Vary by Model)
Width20"
Height8"
Depth2"
Weight8.00 lb

What's included?

  • RED LED Combo Exit Sign / Emergency Light
  • Two "EXIT" Faceplates (with optional knockout arrows)
  • One Blank Faceplate
  • Mounting Canopy, Installation Instructions & Hardware (Inside Unit)
  • NiCad Battery - Must connect the battery after installation

Construction

The COMBO2-R series is constructed from injection-molded, high-impact, engineering-grade, 5VA flame retardant thermoplastic. White housing is standard.

Illumination

Emergency lamps use long-lasting, energy efficient ultra bright white LEDs. Heads are made with high-performance chromeplated reflectors and polycarbonate lenses for optimal light distribution. Exit portion uses red or green LEDs.

Emergency Operation

Upon failure of the normal utility power, an internal solidstate transfer switch automatically provides uninterrupted emergency operation for at least 90 minutes. The fully automatic solid-state, two-rate charger initiates recharging a discharged battery within 24 hours.

Battery - Battery Backup

The COMBO2-R Combo Exit Light is designed with a maintenance-free 3.6V 100mAh NiCad battery that provides a minimum emergency duration of 90 minutes. Recharge time of the battery is 24 hours.

Operational Temperature

Temperature Ratings
Standard Option32°F to 104°F

Photometrics

Total Luminaire Lumens : 275lm

Download .IES File

Suggested mounting height of 7.5ft illuminates 1 footcandle (FC) spaced at 18ft for a 3ft path of egress.

Disclosure:

Spacing is measured in lab condition with an assumed open space, no obstruction and reflection rates of 80 (ceiling) / 50 (walls) / 20 (floor). Actual spacing may vary depending on what environment the fixture is installed in.

Standard Red LED Exit Light Combo | 180° Adjustable Head Photometrics

Self-Testing Option

Unit continuously monitors the AC power, battery supply voltage, emergency lamp condition and charging circuit. If failure is detected, the indicator will show status and correct when adjusted. Unit will automatically perform NFPA required monthly and annual testing. Refer to user manual for details.

Remote Head Capable Option

The remote head capability option allows the COMBO2 unit to supply power to up to two additional 3.6V LED remote heads. The remote heads would then operate on the same emergency mode as the standard units (see Emergency Operation Section).

Electrical Components

120/277 VAC operation. LED display indicates AC/ON. An external push button test switch allows maintenance personnel to quickly determine the operational status of the unit. Unit offers surge protected, solid state circuitry.

Installation

The COMBO2-R is suitable for surface wall and top mounting via included canopy. Snap together design allows for quick and easy installation. Knock-out chevrons for customized egress signage.

Mounting Configurations   Mounting Configurations Explained

PDF Download   View Installation Instructions

Dimensions

Standard Red LED Exit Light Combo | 180° Adjustable Head Dimensions

Customer Questions & Answers
Post a question and have an expert answer



Q joe meath • 02/05/2021, 4:03:44 PM I need high lumen lights to light up the room. How many lumens are the lights attached to the exit signs
A Exit Light Co. The combo exit signs provides 60lm per square heads, totaling 120lm.
Q Patty • 12/02/2022, 2:21:48 PM Does this sign have to be plugged into an AC/DC outlet, or is it powered by the Nicad battery? Is it just the lamps that need electrical power?
A Exit Light Co. The COMBO2-R unit does need to be connected to power. This unit is usually hard wired to the electrical system in the building, but it can be ordered with a 3’ cord instead, which can be plugged into any standard wall outlet. The nicad battery is to operate the light when a loss of power is detected. It should run for 90 minutes, when fully charged.
Q Daniel Coe • 03/02/2023, 4:08:02 AM Is this fixture compatible with a 230/400-volt 50-Hz power supply?
A Exit Light Co. This unit only works on 120/277 V.
Q Robert • 03/09/2023, 9:32:19 PM Where is the test button/ indicator led?
A Exit Light Co. The test button and indicator light are located near the bottom on the side.
Q EUGENE ETHERIDGE • 06/21/2023, 12:06:53 PM I see a three-foot cord is optional. Does this unit get directly wired into our building?
A Exit Light Co. Usually yes, the COMBO2 unit is hardwired into the building's electrical system. Selecting the 3' cord option allows the unit to connect to the electrical system simply by being plugged into a standard wall outlet.
Q Gary hilbert • 08/31/2023, 7:42:14 PM Is the body of the unit 8.5 x 20? Need to cover an old flush mounted hole.
A Exit Light Co. The approximate 20” is referring to the overall length, including emergency lights on the side of the unit.
Q Richard A Walker • 01/29/2024, 10:57:26 AM Where is the Self-Test status indicator located?
A Exit Light Co. Depending on the exact model shipped, it will either be on the bottom of the unit or on the side, near the bottom. In either position, it is in an easy to read location.